Products  |  Software  |  Services  |  Solutions  |  Support  |  Supplies  
My OcéContact Océ
Download Océ security patch for MS08-037
/NR/rdonlyres/e34dbdzsp5a6bpvpaby5whh7u2i4xbnerjnadr7ygfe5t2um22jkkrcphpdtk73lz6simtl6ve4yoj/_TemplateResource2.gif
 
 
 
 
Last version of TDS/TCS systems allow to apply the patch remotely with the new Océ Remote Patch procedure. With those versions, there is no need to build floppy or CD-ROM to apply the patch. The Océ remote patch procedure is realized through HTTP protocol with a Web browser.
 
The TDS/TCS versions compatible with Océ Remote Patch procedure are mentionned in the table below.
You can also check whether the TDS/TCS system is compatible with Océ Remote Patch procedure :
                        
1.   From a client Web browser, enter the following URL :
 
http://<tds-tcs_hostname_or_ip_address>/OceRemotePatch.html
 
where <tds-tcs_system_hostname_or_ip_address> is the hostname or IP address of the TDS-TCS system
Note : Please respect lowercase/uppercase for "OceRemotePatch.html"
 
2.   If the following page appears :
 
Your TDS-TCS system is compatible with Océ Remote Patch procedure, so follow the instructions below, otherwise click here to apply the patch  with a media (floppy or cd-rom)
 
Océ Remote Patch is available for
Océ TDS400 2.1.9 
Océ TDS450 3.3 
Océ TDS600 4.1.9
Océ TDS700 1.2 
Océ TDS800 2.1.9 
Océ TDS860 1.0.9 
Océ TCS400 2.2.9 
Océ TCS500 1.4 
 
Microsoft bulletin
MS08-037
Océ Remote patch

Name:   patch_remote_shf017b.oce
Size:
 1 054 Kb
Revision date: 8/12/2008

Download now » (registration required)

See below for installation instrutions

 
 
 
 
 
 

  
 
Patch installation instructions for systems supporting Océ Remote patch procedure :
 
     1.   Download the patch file patch_remote_shf017b.oce and save the
           file on your computer
           (Win98/WinMe/Win2000/WinXP/Winserver2003/Vista)
 
 
     2.   From a Web browser (on your computer), enter the following URL :
 
http://<tds-tcs_hostname_or_ip_address>/OceRemotePatch.html
 
where <tds-tcs_system_hostname_or_ip_address> is the hostname or IP address of the TDS-TCS system
Note : Please respect lowercase/uppercase for "OceRemotePatch.html"
 
     3.   When the following page appears, enter the password (see your
           Printer User manual) :
 
 
  
     4.   When the following page appears, browse for the patch previously
           downloaded :
 
 
 
 
    5.   When clicking on "Apply Patch" a confirmation popup
          window will appear. After you will confirm, some
          information will be displayed on the screen to inform
          you on the patch process. When you'll see the
          following
 information message, the controller will reboot
          in order
to complete the patch application :
 
The controller will be restarted...
Waiting for PLC patch process to end...
 
 
    6.   After a little while, you'll be able after refreshing the
         URL to see the following page again (after controller
         will have been rebooted) :
 
 
 
 
     7.  After having entered the relevant password (Please
          see your Printer User manual), the following page will
          appear, and you can control whether the patch has
          been installed :
            * latest successful installed patch
            * last execution status : ... Success
 
 
_____________________________________________________
_____________________________________________________
 
             
Patch for
Océ TDS300 1.1.9/1.1.8.1/1.1.5
Océ TDS320 1.0.9/1.0.8.1/1.0.8/1.0.2
Océ TDS400 2.1.9/2.1.8.1/2.1.5
Océ TDS450 3.3 and lower versions
Océ TDS600 4.1.9/4.1.8.1/4.1.8/4.1.6
Océ TDS700 1.2 and lower versions
Océ TDS800 2.1.9/2.1.8.1/2.1.5
Océ TDS860 1.0.9/1.0.8.1/1.0.8/1.0.3
Océ TCS300 1.2 and lower versions
Océ TCS400 2.2.9/2.2.6/2.2.5
Océ TCS500 1.4 and lower versions
Microsoft bulletin
MS08-037
File details for systems equipped with a Floppy unit

Name:   patch_shf017b.exe
Size:
 1 292 Kb
Revision date: 8/12/2008

Download now » (registration required)

Click here for installation instrutions

File details for systems NOT equipped with a Floppy unit

Name:   patch_shf017b.iso
Size:
 1 108 Kb
Revision date: 8/12/2008

Download now » (registration required)

Click here for installation instructions

 
 
 
 
     1.   Download the patch file patch_shf017b.exe and save the file on
           your computer(Win98/WinMe/Win2000/WinXP/Winserver2003
           /Vista)
 
     2.   Create a floppy containing the patch :
 
           - Doubleclick on the saved file (It is an executable which will
             guide you through the creation process of the patch diskette)
           - Follow the instructions on the screen
 
     3.  Shutdown the Océ Power Logic Controller

     4.  Insert the previously created patch diskette  in the 
          Océ Power Logic controller floppy drive.
 
     5.  Power ON the Océ Power Logic Controller.
 
     6.  Wait until the patch is applied  : a melody is played
          (you will hear 2 times a 3 tonal beeps)
                - it should take about ~3 minutes on a GX280 PC
                - before the melody is played, a PC reboot will occur
                - For Systems equipped with a monitor, an error message
                  may pop up on the controller screen : Ignore it and let the
                  process go on.
 
     7.  Remove the patch diskette from the floppy drive
 
 
Verifying if the patch was applied successfully
 
     1. Make a « Print settings » (Refer to your Printer User manual for
        more details)

    2. Go to the last printout page in the section:
       SDS - CONTROL PARAMETERS 22-1, the last line is called:
       Patches installed = ………………………… <value>
       Check that « <value> » is greater or equal to 800000000000

 
Troubleshooting
 
    • 2 rapid beeps are played when Patch has already been applied
    • 2 long  beeps are played when Patch file is corrupted
    • Nothing happens or 7 rapid beeps are played when Patch cannot be
       applied (Wrong Océ TDSX00/TCSX00 version)                            
 
 
 
     1.   Download the patch file patch_shf017b.iso and save the file on
           your computer(Win98/WinMe/Win2000/WinXP/Winserver2003
           /Vista)
 
    
     2.   Create a CD-ROM containing the patch from 
              patch_shf017b.iso
:

           Use a CD burner software (like NERO Burner or Roxio Easy
           CD Creator) to burn a CD-R from the attached ISO image
           Advices :To burn a CD-R from this ISO image file, Select an
                         action which "Burn a CD from an Image file",
                         but Do not create a CD-R with the ISO image file on it.
           For example :
                         - With NERO 5.5 Burner : use  File/Burn Image
                         - With Roxio Easy CD Creator 5.1 : use  File/Record CD
                            from CD Image

      3.  Insert the previously created CD-ROM  in the Océ Power Logic
           controller CD drive.
 
      4.  Restart the Océ Power Logic Controller.
 
      5.  Wait until the patch is applied  : a melody is played
          (you will hear 2 times a 3 tonal beeps)
                - it should take about ~3 minutes on a GX260 PC
                - before the melody is played, a PC reboot will occur
                - For Systems equipped with a monitor, an error message
                  may pop up on the controller screen Ignore it and let the
                  process go on.
 
      6.     Remove the CD-ROM from CD drive
 
       
 
Verifying if the patch was applied successfully
 
   1. Make a « Print settings » (Refer to your Printer User manual for
       more details)

   2. Go to the last printout page in the section:
       SDS - CONTROL PARAMETERS 22-1, the last line is called:
       Patches installed = ………………………… <value>
      Check that « <value> » is greater or equal to 800000000000
 
Troubleshooting
 
    • 2 rapid beeps are played when Patch has already been applied
    • 2 long  beeps are played when Patch file is corrupted
    • Nothing happens or 7 rapid beeps or 10 long beeps are played when
       Patch cannot be applied (Wrong Océ TDSX00/TCSX00
       version)  
  
                        
 
Océ Corporate Site
  Home | Products | Software | Services | Solutions | Support | Supplies  
Privacy policy | Terms of use | Other Océ websites »
© 2008 Océ
All rights reserved