| Patch for |
Océ TDS300 1.0.2, 1.1.1, 1.1.2
Océ TDS400 2.0.2, 2.1.1, 2.1.2
Océ TDS600 4.0.2, 4.1.1, 4.1.2
Océ TDS800 2.0.2, 2.1.1, 2.1.2
Océ TDS860 1.0
Océ TCS400 2.2 |
| Microsoft bulletin |
MS05-011 |
| File details |
Name: patch_shf003_1.exe Size: 1382 Kb Revision date: 3/1/2005 Download now » (registration required)
Name: patch_shf003_2.exe Size: 526 Kb Revision date: 3/1/2005 Download now » (registration required)
|
Patch installation instructions
1. Download the 2 patch files mentionned above
patch_shf003_1.exe
patch_shf003_2.exe
and save the 2 files on your computer
(Win98/WinMe/Win2000/WinXP/Winserver2003)
2. Prepare 2 Floppy disks Not write protected
- Doubleclick on the saved file patch_shf003_1.exe (It is an
executable which will guide you through the creation process of the 1st floppy disk)
- a window named "Ardi Version 4.30 (c) Daniel F Valot" opens
- Put a diskette (not write protected) in floppy drive
- click on "OK" in the window
- once the floppy is created, click on "Quit" and label the floppy
"Patch SHF003 Floppy No 1"
- Doubleclick on the saved file patch_shf003_2.exe (It is an executable which wil guide you through the creation process of the 2nd floppy disk) - a window named "Ardi Version 4.30 (c) Daniel F Valot" opens - Put a diskette (not write protected) in floppy drive - click on "OK" in the window - once the floppy is created, click on "Quit" and label the floppy "Patch SHF003 Floppy No 2"
3. Shutdown the Océ Power Logic Controller
4. Insert the 1st floppy disk labelled "Patch SHF003
Floppy No 1" previously created in the Océ Power Logic controller floppy drive.
5. Power ON the Océ Power Logic Controller.
6. Wait until a melody is played (you will hear 2 times a 3 tonal beeps) - it should take about 1 minute 15 seconds on a GX270 PC - For Systems equipped with a monitor, a message
advising to insert the second floppy disk is displayed
7. Power Off the controller, insert the 2nd floppy disk labelled
"Patch SHF003 Floppy No 2" previously created in the Océ Power Logic controller floppy drive.
8. Power ON the Océ Power Logic Controller.
9. Wait until a melody is played (you will hear 2 times a 3 tonal beeps) - it should take about ~3 minutes on a GX270 PC - before the melody is played, a PC reboot will occur - For Systems equipped with a monitor, an error message may pop up on the controller screen Ignore it and let the process go on.
10. Remove the patch diskette from the floppy drive
Verifying if the patch was applied successfully
1. Make a « Print settings » (Refer to your Printer User manual for more details)
2. Go to the last printout page in the section: SDS - CONTROL PARAMETERS 22-1, the last line is called: Patches installed = ………………………… <value>
3. Consult Océ patch(es) identification here with <value>
Troubleshooting
• 2 rapid beeps are played when Patch has already been applied • 2 long beeps are played when Patch file is corrupted • Nothing happens or 7 rapid beeps or 10 long beeps are played when Patch cannot be applied (Wrong Océ TDSX00/TCS400 version)
• if something goes wrong with one of the floppy disk creation,
please check your floppy disks, and restart the complete
procedure
|